{"id":7843,"date":"2024-01-11T02:41:38","date_gmt":"2024-01-11T02:41:38","guid":{"rendered":"https:\/\/www.orielstat.com\/blog\/?p=7843"},"modified":"2024-01-12T20:20:18","modified_gmt":"2024-01-12T20:20:18","slug":"eu-notified-body-review-mdr-technical-documentation","status":"publish","type":"post","link":"https:\/\/www.orielstat.com\/blog\/eu-notified-body-review-mdr-technical-documentation\/","title":{"rendered":"What Notified Bodies Look for When Reviewing Your Medical Device Technical Documentation Under the EU MDR"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"7843\" class=\"elementor elementor-7843\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7388bb3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7388bb3\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4264d41\" data-id=\"4264d41\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-d04a716 blog-details-page elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"d04a716\" data-element_type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;gradient&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-66 elementor-top-column elementor-element elementor-element-e193c4d\" data-id=\"e193c4d\" data-element_type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;gradient&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-aa22ff3 elementor-widget elementor-widget-post-info\" data-id=\"aa22ff3\" data-element_type=\"widget\" data-widget_type=\"post-info.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<link rel=\"stylesheet\" href=\"https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/elementor\/css\/custom-widget-icon-list.min.css?ver=0\"><link rel=\"stylesheet\" href=\"https:\/\/www.orielstat.com\/blog\/wp-content\/plugins\/elementor-pro\/assets\/css\/widget-theme-elements.min.css\">\t\t<ul class=\"elementor-inline-items elementor-icon-list-items elementor-post-info\">\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-7f6be35 elementor-inline-item\" itemprop=\"datePublished\">\n\t\t\t\t\t\t<a href=\"https:\/\/www.orielstat.com\/blog\/2024\/01\/11\/\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-date\">\n\t\t\t\t\t\t\t\t\t\tJanuary 11, 2024\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t<\/li>\n\t\t\t\t<\/ul>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25cfb2d elementor-widget elementor-widget-heading\" data-id=\"25cfb2d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<style>\/*! elementor - v3.16.0 - 17-10-2023 *\/\n.elementor-heading-title{padding:0;margin:0;line-height:1}.elementor-widget-heading .elementor-heading-title[class*=elementor-size-]>a{color:inherit;font-size:inherit;line-height:inherit}.elementor-widget-heading .elementor-heading-title.elementor-size-small{font-size:15px}.elementor-widget-heading .elementor-heading-title.elementor-size-medium{font-size:19px}.elementor-widget-heading .elementor-heading-title.elementor-size-large{font-size:29px}.elementor-widget-heading .elementor-heading-title.elementor-size-xl{font-size:39px}.elementor-widget-heading .elementor-heading-title.elementor-size-xxl{font-size:59px}<\/style><h1 class=\"elementor-heading-title elementor-size-default\">What Notified Bodies Look for When Reviewing Your Medical Device Technical Documentation Under the EU MDR<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78a7c7e elementor-widget elementor-widget-image\" data-id=\"78a7c7e\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<style>\/*! elementor - v3.16.0 - 17-10-2023 *\/\n.elementor-widget-image{text-align:center}.elementor-widget-image a{display:inline-block}.elementor-widget-image a img[src$=\".svg\"]{width:48px}.elementor-widget-image img{vertical-align:middle;display:inline-block}<\/style>\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"2560\" height=\"1710\" src=\"https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2020\/05\/Notified-Body-Reviewing-EUMDR-Tech-Doc-scaled.jpg\" class=\"attachment-full size-full wp-image-2947\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2020\/05\/Notified-Body-Reviewing-EUMDR-Tech-Doc-scaled.jpg 2560w, https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2020\/05\/Notified-Body-Reviewing-EUMDR-Tech-Doc-300x200.jpg 300w, https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2020\/05\/Notified-Body-Reviewing-EUMDR-Tech-Doc-1024x684.jpg 1024w, https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2020\/05\/Notified-Body-Reviewing-EUMDR-Tech-Doc-768x513.jpg 768w, https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2020\/05\/Notified-Body-Reviewing-EUMDR-Tech-Doc-1536x1026.jpg 1536w, https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2020\/05\/Notified-Body-Reviewing-EUMDR-Tech-Doc-2048x1368.jpg 2048w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7a5edb elementor-widget elementor-widget-text-editor\" data-id=\"f7a5edb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<style>\/*! elementor - v3.16.0 - 17-10-2023 *\/\n.elementor-widget-text-editor.elementor-drop-cap-view-stacked .elementor-drop-cap{background-color:#69727d;color:#fff}.elementor-widget-text-editor.elementor-drop-cap-view-framed .elementor-drop-cap{color:#69727d;border:3px solid;background-color:transparent}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap{margin-top:8px}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap-letter{width:1em;height:1em}.elementor-widget-text-editor .elementor-drop-cap{float:left;text-align:center;line-height:1;font-size:50px}.elementor-widget-text-editor .elementor-drop-cap-letter{display:inline-block}<\/style>\t\t\t\t<p>If you\u2019ve been involved in medical device regulatory affairs for 5+ years, you know all too well that the requirements around technical documentation associated with European CE Marking have tightened. The MEDDEV 2.7-1 rev 4 guidance on clinical evaluations \u2013 in addition to the MDR and updates ISO 14971 risk management standard \u2013 gave many regulatory professionals heartburn.<\/p><p><em><strong>Why the deluge?<\/strong>\u00a0<\/em>Here&#8217;s one factor. About 10 years ago, the French PIP breast implant scandal rocked the Notified Body world and made European Competent Authorities (Ministries of Health) stand up and take notice. EU regulators recognized a need to overhaul the regulation of medical devices and have stricter oversight of the Notified Bodies designated to regulate medical device manufacturers on their behalf. As such, Notified Bodies are increasingly under the microscope of regulatory scrutiny from the top down. That\u2019s why the MDD was replaced with the much stricter Medical Device Regulation (MDR 2017\/745).<\/p><p>So, now that\u00a0<strong>the bar for technical documentation has been raised<\/strong>, it begs the question: What will EU Notified Bodies be looking for during your next technical documentation review? If you have not yet had the pleasure of going through this, you may have some trepidation about what to expect. That&#8217;s understandable. Often, Notified Bodies will audit your QMS on-site while they conduct a remote review of your technical documentation for CE Marking. Although regulatory professionals especially for Class I and IIa devices have been working on strengthening their technical documentation for years, many have not yet had their technical documentation put to the test under the MDR.<\/p><div class=\"box-cur\"><strong>We make several references to specific Annexes and Chapters of the EU MDR in this article.\u00a0<i>Simplify your life by downloading a\u00a0<a href=\"https:\/\/www.orielstat.com\/blog\/table-contents-eu-mdr-2017745\/\" target=\"_blank\" rel=\"noopener noreferrer\">PDF<\/a>\u00a0containing the full text of the MDR, including a linked Table of Contents.<\/i><\/strong><\/div><h3>\u00a0<\/h3><h3>What Your EU Notified Body Is Required to Do?<\/h3><p>Here&#8217;s how things typically work. Your Notified Body would issue an MDD CE certificate valid for five years. The MDR essentially forces an automatic review of one or more of your technical documentation files during every surveillance audit. This means that under the EU MDR your device is approved for <u>up to<\/u>\u00a0five years but not automatically approved for a five-year term, as issues may be uncovered during a routine QMS audit. The intent of this sampling of technical documentation under the EU MDR is to prevent the type of occurrences that happened under the MDD. Plainly put, Notified Bodies often were not seeing changes made to products over time and a cursory review every five years was not sufficient. That\u2019s also why Article 120(3) exists in the MDR \u2013 to define what is considered a significant change.<\/p><p>How might this play out? Here&#8217;s a real-world scenario. Your device might be three years into a five-year term and, during a surveillance audit, your Notified Body may ask you to provide additional and more detailed information about technical documentation. In this manner, the European model is moving more toward the US model whereby FDA inspects not only the quality management system but also product information too, even if a device already has 510(k) clearance.<\/p><p>Its helpful to understand what your Notified Body\u00a0<strong>must<\/strong>\u00a0do as part of the technical documentation review. By the way, this technical documentation review can occur either remotely as part of obtaining a CE certificate or during a routine QMS audit. According to Annex VII of the EU MDR, your Notified Body must:<\/p><ul><li>Assess your technical documentation based on its predefined sampling plan.<\/li><li>Assess your product technical documentation safety and performance requirements: Annex I.<\/li><li>Take into account requirements related to preclinical testing and clinical evaluations.<\/li><li>Ensure that technical documentation findings are appropriately and consistently classified based on a procedure to assess compliance with requirements of the EU MDR and relevant standards.<\/li><\/ul><p>The auditor examining your documentation must have proven knowledge and experience, and understand the device technology and its clinical application. In some cases the auditor may bring in external experts who have direct or current expertise with the device and the clinical conditions in which it is used. You can read extensive information on this in Section 3 of Annex VII.<\/p><h3>\u00a0<\/h3><h3>General Safety and Performance Requirements (GSPR)<\/h3><p><strong>Annex I:<\/strong> it all starts here, and you may recall these requirements being called the Essential Requirements in the MDD. To better define their intent, the EU MDR now calls these General Safety and Performance Requirements (GSPR). Frankly, many Notified Bodies used to gloss over the Essential Requirements during an audit, but not any longer. Notified Bodies now use these requirements as a backbone of their review and apply them using a traceability matrix. You&#8217;ll definitely want to study and follow these requirements because you can bet that your Notified Body will use them as a guide.<\/p><h3>\u00a0<\/h3><h3>Key Areas Likely to Be Scrutinized<\/h3><p>You can expect your Notified Body to dig deep into many areas of your technical documentation, but you would be well advised to pay special attention to the following areas:<\/p><ul><li><strong>Clinical data\u00a0<\/strong>Consider this: The MDD mentions the word\u00a0<em>clinical<\/em>\u00a0just 48 times. In the MDR, it is mentioned 684 times. Factoid aside, you already knew this was important because you have read MEDDEV 2.7-1 rev 4, right\u2019 As such, you can expect intense scrutiny of your clinical evidence and supporting clinical data of the device. If your clinical data is lacking, your Notified Body may require more physical or laboratory tests. See Annex IX, Chapter II.<\/li><li><strong>Intended purpose, indications for use, and claims<\/strong>\u00a0If your devices intended purpose and indications for use are fairly broad, it may be time to tighten them up. Notified Bodies will be looking at your specific claims and how they are supported by your clinical data. That will be especially true for Class I devices that were formerly self-declared but are now subject to EU MDR oversight.<\/li><li><strong>Equivalency\u00a0<\/strong>Are you claiming equivalence with another medical device\u2019 If so, you&#8217;ll want to read <a href=\"https:\/\/www.orielstat.com\/blog\/eu-mdr-device-equivalency\/\" target=\"_blank\" rel=\"noopener noreferrer\">this article<\/a>. From the Notified Body perspective, they are going to carefully scrutinize your clinical evidence to assess the suitability of using that data. They will be looking at specific claims and whether they are supported by preclinical data, clinical data, and risk analysis. Notified Bodies are also required to document their conclusions about your equivalence claims and whether they are adequate to demonstrate conformity with the GSPR. If your device is innovative or has new indications for use, don&#8217;t be surprised if your Notified Body requires more testing to be done.<\/li><li><strong>Labeling<\/strong>\u00a0Expect your Notified Body to carefully examine your instructions for use and tie them back to your stated claims and intended purpose. If materials are an important part of your device (e.g., implants), expect your materials disclosure to receive attention.<\/li><li><strong>Performance testing<\/strong>\u00a0Many companies have conducted lab testing for their devices, and this was often fine under the MDD regime. In the past, some companies performed lab testing on individual components but did not validate the entire system. (Blood glucose meters are a good example of this.) Notified Bodies want to see more emphasis on product validation measuring performance in an actual use environment.<\/li><li><strong>Benefit-risk analysis<\/strong>\u00a0You are certainly familiar with ISO 14971 and risk management, having been in the medical industry for many years. The EU MDR (and ISO 14971:2019) now stress the importance of measuring benefits, not just risks. If you have not yet done work to shore up your benefit-risk analysis, read\u00a0<a href=\"https:\/\/www.orielstat.com\/blog\/evaluating-medical-device-benefits\/\" target=\"_blank\" rel=\"noopener noreferrer\">this excellent article<\/a>\u00a0on doing so.<\/li><li><strong>Residual risk\u00a0<\/strong>ISO 14971:2019 and the EU MDR also emphasize the need to reduce risk to the lowest levels practicable. As such, your Notified Body will be looking into your risk analysis more closely, especially your assessment of residual risk. This feeds into the general narrative that risk management should be a continual process, and youll need to show proof that you are treating it as such.<\/li><li><strong>Postmarket Surveillance (PMS)\u00a0<\/strong>PMS data is more important than ever to regulators, and follows the general line of thinking that risk management is not a one and done project but rather an ongoing process. Expect your Notified Body to request proof showing that you have been proactive in your PMS efforts.<\/li><\/ul><h3>\u00a0<\/h3><h3>How Notified Bodies Choose Which Documentation to Review?<\/h3><p>Annex IX, Section 2.3 talks about how Notified Bodies must select samples of your technical documentation and the need to document their rationale for their selection of samples. Their sampling must take the following into account:<\/p><ul><li>Risks associated with the intended use of the device<\/li><li>Novelty of the technology and similarities in design and sterilization methods<\/li><li>Complexity of the manufacturing process<\/li><li>Results of any previous relevant assessments and nonconformities raised related to physical, chemical, biological, or clinical properties<\/li><li>Range and classes of devices produced<\/li><li>Available postmarket surveillance information<\/li><li>Prevalence and volume of distribution into Europe for a product type<\/li><\/ul><hr \/><p>\u00a0<\/p><p><strong><i>Here&#8217;s a pro tip from BSI, the largest European medical device Notified Body:<\/i><\/strong>\u00a0<em>as far as is practical, [MDR] submissions should be stand alone, and not refer to previous [MDD] submissions for evidence of compliance. The reason is that the reviewer must assess the documentation in the context of the intended submission and confirm that it is still relevant within this context. If a submission draws upon information previously submitted to BSI, please include the relevant report or document which demonstrates compliance, rather than directing the reviewer to the earlier review. This will save time<\/em>.<\/p><hr \/><h3>\u00a0<\/h3><h3>European Competent Authorities Are Watching Too<\/h3><p>Typically, European Competent Authorities have kept a low profile, especially when it comes to low- and medium-risk devices (which comprise 95% of device volume). But now manufacturers especially self-declared Class I devices can expect to see more market surveillance from Competent Authorities. We have seen evidence of Competent Authorities in the Netherlands and Belgium, for example, inspecting Class I self-declared manufacturers! In the near term, you can expect to see more involvement from Competent Authorities, but this is also part of a longer-term trend to assert more control for reasons explained earlier.<\/p><h3>\u00a0<\/h3><h3>Want to Learn More?<\/h3><p>Regardless of where you are on the EU MDR knowledge ladder, we have the training and consulting support to help.<\/p><p>On the training side, our\u00a0<a href=\"https:\/\/www.orielstat.com\/courses\/eu-mdr-training\">our EU MDR overview\u00a0<\/a>class will get you up to speed quickly while our\u00a0<a href=\"https:\/\/www.orielstat.com\/courses\/eu-mdr-auditor-training-2017-745\">EU MDR Auditor class<\/a>\u00a0teaches experienced auditors how to audit to the MDR.<\/p><p>On the consulting side, our EU MDR team can help review and structure your Technical Documentation in accordance with EU MDR requirements.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3400fd elementor-widget elementor-widget-shortcode\" data-id=\"a3400fd\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-shortcode\"><div class=\"container\">\n    <div class=\"col-lg-12 col-md-12\">\n        <h5 class=\"elementor-heading-title elementor-size-default\">Our team is here to help. <a href=\"javascript:void(0);\" rel=\"nofollow\" noindex=\"noindex\">Contact us online<\/a><\/h5>\n        <h5 class=\"elementor-heading-title elementor-size-default\">or<\/h5>\n        <h6 class=\"elementor-heading-title elementor-size-default\">Get answers right now. Call<\/h6>\n    <\/div>\n    <div id=\"Bottom_icons1_DivOfficePhone\" class=\"row new_update_add\">\n<div class=\"col-lg-6 col-md-12 borderbottom\">\n <div class=\"block-text1\">\n     <img decoding=\"async\" src=\"https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2023\/11\/us-flag.jpg\">\n     <p>\n         <b>US Office<\/b>Washington DC<\/p>\n <\/div>\n <p>\n     <a href=\"tel:1.800.472.6477\">1.800.472.6477<\/a><\/p>\n<\/div>\n<div class=\"col-lg-6 col-md-12\">\n <div class=\"block-text1\">\n     <p>\n         <b>EU Office<\/b>Cork, Ireland<\/p>\n     <img decoding=\"async\" src=\"https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2023\/11\/eu-flag.jpg\" class=\"img-right-sec\">\n <\/div>\n <p>\n     <a href=\"tel:+353 21 212 8530\">+353 21 212 8530<\/a><\/p>\n<\/div>\n<\/div>\n<\/div><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-d2b128c\" data-id=\"d2b128c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3de1869 elementor-widget elementor-widget-sidebar\" data-id=\"3de1869\" data-element_type=\"widget\" data-widget_type=\"sidebar.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<section id=\"search-2\" class=\"widget widget_search\"><form role=\"search\" method=\"get\" class=\"search-form\" action=\"https:\/\/www.orielstat.com\/blog\/\">\n\t\t\t\t<label>\n\t\t\t\t\t<span class=\"screen-reader-text\">Search for:<\/span>\n\t\t\t\t\t<input type=\"search\" class=\"search-field\" placeholder=\"Search &hellip;\" value=\"\" name=\"s\" \/>\n\t\t\t\t<\/label>\n\t\t\t\t<input type=\"submit\" class=\"search-submit\" value=\"Search\" \/>\n\t\t\t<\/form><\/section><section id=\"block-2\" class=\"widget widget_block\">\n<figure class=\"wp-block-image size-large\"><a href=\"#mailmunch-pop-545876\"><img decoding=\"async\" src=\"https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2017\/06\/Blog-subscribe.jpg\" alt=\"\"><\/a><\/figure><\/section><section id=\"categories-3\" class=\"widget widget_categories\"><h2 class=\"widget-title\">Search by Topic<\/h2>\n\t\t\t<ul>\n\t\t\t\t\t<li class=\"cat-item cat-item-12\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/all-medical-device-ra-qa\/\">All Category<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-74\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/ai\/\">Artificial Intelligence (AI)<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-64\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/auditing\/\">Auditing<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-71\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/capa\/\">CAPA<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-20\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/capa-for-medical-devicecompliance\/\">CAPA and Root Cause Analysis<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-27\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/clinical-evaluation-reports\/\">Clinical Evaluation Reports<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-59\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/combination-products\/\">Combination Products<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-23\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/complaint-handling-postmarket-surveillance\/\">Complaint Handling and PMS<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-33\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/design-control\/\">Design Control<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-34\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/in-vitro-diagnostics-ivdr\/\">EU IVDR (2017\/746)<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-16\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/eu-medical-device-regulation\/\">EU MDR (2017\/745)<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-14\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/us-fda-qsr\/\">FDA 21 CFR Part 820<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-21\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/510k-submissions\/\">FDA 510(k) Submissions<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-69\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/fda-eua\/\">FDA EUA<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-4\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/iso-134852016\/\">ISO 13485 QMS Compliance<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-30\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/risk-management-iso14971\/\">ISO 14971 Risk Management<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-40\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/laboratory-developed-tests-ldt\/\">Lab Developed Tests<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-66\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/labeling\/\">Labeling<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-18\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/mdsap\/\">MDSAP<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-58\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/pharmaceutical\/\">Pharmaceuticals<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-28\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/qms-auditing\/\">QMS Auditing<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-72\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/qmsr\/\">QMSR<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-73\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/regulatory-compliance\/\">Regulatory Compliance<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-65\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/software\/\">Software<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-63\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/software-cybersecurity\/\">Software and Cybersecurity<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-32\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/supplier-management\/\">Supplier Management<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-67\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/training\/\">Training<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-1\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/medical-device-ra-qa\/\">Uncategorized<\/a>\n<\/li>\n\t<li class=\"cat-item cat-item-35\"><a href=\"https:\/\/www.orielstat.com\/blog\/category\/validation\/\">Validation<\/a>\n<\/li>\n\t\t\t<\/ul>\n\n\t\t\t<\/section>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>What Notified Bodies Look for When Reviewing Your Medical Device Technical Documentation Under the EU MDR If you\u2019ve been involved in medical device regulatory affairs for 5+ years, you know all too well that the requirements around technical documentation associated with European CE Marking have tightened. The MEDDEV 2.7-1 rev 4 guidance on clinical evaluations [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2947,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_header_footer","format":"standard","meta":[],"categories":[64],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.7 (Yoast SEO v21.7) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\r\n<title>Oriel STAT A MATRIX &#8211; ELIQUENT Life Sciences Blog<\/title>\r\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\r\n<link rel=\"canonical\" href=\"https:\/\/www.orielstat.com\/blog\/eu-notified-body-review-mdr-technical-documentation\/\" \/>\r\n<meta property=\"og:locale\" content=\"en_US\" \/>\r\n<meta property=\"og:type\" content=\"article\" \/>\r\n<meta property=\"og:description\" content=\"What Notified Bodies Look for When Reviewing Your Medical Device Technical Documentation Under the EU MDR If you\u2019ve been involved in medical device regulatory affairs for 5+ years, you know all too well that the requirements around technical documentation associated with European CE Marking have tightened. The MEDDEV 2.7-1 rev 4 guidance on clinical evaluations [&hellip;]\" \/>\r\n<meta property=\"og:url\" content=\"https:\/\/www.orielstat.com\/blog\/eu-notified-body-review-mdr-technical-documentation\/\" \/>\r\n<meta property=\"og:site_name\" content=\"Oriel STAT A MATRIX - ELIQUENT Life Sciences Blog\" \/>\r\n<meta property=\"article:published_time\" content=\"2024-01-11T02:41:38+00:00\" \/>\r\n<meta property=\"article:modified_time\" content=\"2024-01-12T20:20:18+00:00\" \/>\r\n<meta property=\"og:image\" content=\"https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2020\/05\/Notified-Body-Reviewing-EUMDR-Tech-Doc-scaled.jpg\" \/>\r\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\r\n\t<meta property=\"og:image:height\" content=\"1710\" \/>\r\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\r\n<meta name=\"author\" content=\"usr192162\" \/>\r\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\r\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"usr192162\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\r\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Oriel STAT A MATRIX &#8211; ELIQUENT Life Sciences Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.orielstat.com\/blog\/eu-notified-body-review-mdr-technical-documentation\/","og_locale":"en_US","og_type":"article","og_description":"What Notified Bodies Look for When Reviewing Your Medical Device Technical Documentation Under the EU MDR If you\u2019ve been involved in medical device regulatory affairs for 5+ years, you know all too well that the requirements around technical documentation associated with European CE Marking have tightened. The MEDDEV 2.7-1 rev 4 guidance on clinical evaluations [&hellip;]","og_url":"https:\/\/www.orielstat.com\/blog\/eu-notified-body-review-mdr-technical-documentation\/","og_site_name":"Oriel STAT A MATRIX - ELIQUENT Life Sciences Blog","article_published_time":"2024-01-11T02:41:38+00:00","article_modified_time":"2024-01-12T20:20:18+00:00","og_image":[{"width":2560,"height":1710,"url":"https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2020\/05\/Notified-Body-Reviewing-EUMDR-Tech-Doc-scaled.jpg","type":"image\/jpeg"}],"author":"usr192162","twitter_card":"summary_large_image","twitter_misc":{"Written by":"usr192162","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.orielstat.com\/blog\/eu-notified-body-review-mdr-technical-documentation\/#article","isPartOf":{"@id":"https:\/\/www.orielstat.com\/blog\/eu-notified-body-review-mdr-technical-documentation\/"},"author":{"name":"usr192162","@id":"https:\/\/www.orielstat.com\/blog\/#\/schema\/person\/a775f07c9602a3521143e80692594553"},"headline":"What Notified Bodies Look for When Reviewing Your Medical Device Technical Documentation Under the EU MDR","datePublished":"2024-01-11T02:41:38+00:00","dateModified":"2024-01-12T20:20:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.orielstat.com\/blog\/eu-notified-body-review-mdr-technical-documentation\/"},"wordCount":1776,"publisher":{"@id":"https:\/\/www.orielstat.com\/blog\/#organization"},"articleSection":["Auditing"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.orielstat.com\/blog\/eu-notified-body-review-mdr-technical-documentation\/","url":"https:\/\/www.orielstat.com\/blog\/eu-notified-body-review-mdr-technical-documentation\/","name":"","isPartOf":{"@id":"https:\/\/www.orielstat.com\/blog\/#website"},"datePublished":"2024-01-11T02:41:38+00:00","dateModified":"2024-01-12T20:20:18+00:00","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.orielstat.com\/blog\/eu-notified-body-review-mdr-technical-documentation\/"]}]},{"@type":"WebSite","@id":"https:\/\/www.orielstat.com\/blog\/#website","url":"https:\/\/www.orielstat.com\/blog\/","name":"Oriel STAT A MATRIX Blog","description":"","publisher":{"@id":"https:\/\/www.orielstat.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.orielstat.com\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.orielstat.com\/blog\/#organization","name":"Oriel STAT A MATRIX Blog","url":"https:\/\/www.orielstat.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.orielstat.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2024\/01\/OSAM-Eliquent-logo-color.png","contentUrl":"https:\/\/www.orielstat.com\/blog\/wp-content\/uploads\/2024\/01\/OSAM-Eliquent-logo-color.png","width":1458,"height":1042,"caption":"Oriel STAT A MATRIX Blog"},"image":{"@id":"https:\/\/www.orielstat.com\/blog\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.orielstat.com\/blog\/#\/schema\/person\/a775f07c9602a3521143e80692594553","name":"usr192162","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.orielstat.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/1412cb81dc66fbc000fb222b1ea52700?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1412cb81dc66fbc000fb222b1ea52700?s=96&d=mm&r=g","caption":"usr192162"},"url":"https:\/\/www.orielstat.com\/blog\/author\/usr192162\/"}]}},"_links":{"self":[{"href":"https:\/\/www.orielstat.com\/blog\/wp-json\/wp\/v2\/posts\/7843"}],"collection":[{"href":"https:\/\/www.orielstat.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.orielstat.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.orielstat.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.orielstat.com\/blog\/wp-json\/wp\/v2\/comments?post=7843"}],"version-history":[{"count":4,"href":"https:\/\/www.orielstat.com\/blog\/wp-json\/wp\/v2\/posts\/7843\/revisions"}],"predecessor-version":[{"id":7847,"href":"https:\/\/www.orielstat.com\/blog\/wp-json\/wp\/v2\/posts\/7843\/revisions\/7847"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.orielstat.com\/blog\/wp-json\/wp\/v2\/media\/2947"}],"wp:attachment":[{"href":"https:\/\/www.orielstat.com\/blog\/wp-json\/wp\/v2\/media?parent=7843"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.orielstat.com\/blog\/wp-json\/wp\/v2\/categories?post=7843"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.orielstat.com\/blog\/wp-json\/wp\/v2\/tags?post=7843"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}